SupplyGopher

Plumbing fixture count calculator

Pick the use of the building and enter the occupant load. The calculator gives the minimum water closets, lavatories, bathtubs or showers, and drinking fountains from Table 403.1 of the 2021 International Plumbing Code, with the printed ratio, the section it comes from, and the arithmetic. It covers that one code. California and some other jurisdictions use a different plumbing code or amend this one, so confirm with your local authority. When the counts are right, one click opens them in the restroom builder to price the accessories, and the ADA mounting heights chart has the heights.

Required fixtures

Buildings for the transaction of business, professional services, other services involving merchandise, office buildings, banks, ambulatory care, light industrial and similar uses. Occupant load 100: 50 male and 50 female.

Water closets

  • 2

    Water closets, male

    Table says: 1 per 25 for the first 50 and 1 per 50 for the remainder exceeding 50

    Working: 50 ÷ 25 = 2 (within the first 50)

    IPC 2021, Table 403.1, Section 403.1.1

  • 2

    Water closets, female

    Table says: 1 per 25 for the first 50 and 1 per 50 for the remainder exceeding 50

    Working: 50 ÷ 25 = 2 (within the first 50)

    IPC 2021, Table 403.1, Section 403.1.1

Up to 1 of the 2 male water closets can be replaced by urinals (50 percent limit).

IPC 2021, Section 424.2: “In each bathroom or toilet room, urinals shall not be substituted for more than 67 percent of the required water closets in assembly and educational occupancies. Urinals shall not be substituted for more than 50 percent of the required water closets in all other occupancies.”

Lavatories

  • 2

    Lavatories, male

    Table says: 1 per 40 for the first 80 and 1 per 80 for the remainder exceeding 80

    Working: 50 ÷ 40 = 1.25, round up to 2 (within the first 80)

    IPC 2021, Table 403.1, Section 403.1.1

  • 2

    Lavatories, female

    Table says: 1 per 40 for the first 80 and 1 per 80 for the remainder exceeding 80

    Working: 50 ÷ 40 = 1.25, round up to 2 (within the first 80)

    IPC 2021, Table 403.1, Section 403.1.1

  • IPC 2021, Section 403.1.3: “Where two or more toilet rooms are provided for each sex, the required number of lavatories shall be distributed proportionately to the required number of water closets.”

  • IPC 2021, Section 419.1: “For determining the number of lavatories required by Table 403.1, every 20 inches (508 mm) of rim space of a group wash fixture shall be considered as one lavatory.”

Bathtubs or showers

  • 0

    Bathtubs or showers

    Table says: None

    Working: The table lists none for this use.

    IPC 2021, Table 403.1

Drinking fountains

  • 1

    Drinking fountains

    Table says: 1 per 100

    Working: 100 ÷ 100 = 1

    IPC 2021, Table 403.1

  • IPC 2021, Section 410.2: “Drinking fountains shall not be required for an occupant load of 15 or fewer.”

  • IPC 2021, Section 410.3.1: “Not fewer than two drinking fountains shall be provided. One drinking fountain shall comply with the requirements for people who use a wheelchair and one drinking fountain shall comply with the requirements for standing persons.”

  • IPC 2021, Section 410.4: “Where restaurants provide drinking water in a container free of charge, drinking fountains shall not be required in those restaurants. In other occupancies where three or more drinking fountains are required, water dispensers shall be permitted to be substituted for not more than 50 percent of the required number of drinking fountains.”

  • IPC 2021, Section 410.5: “Drinking fountains, water coolers and water dispensers shall not be installed in public restrooms.”

Other

  • Check input

    Other

    Table says: 1 service sink

    Working: As printed in the table.

    IPC 2021, Table 403.1

Rules that apply to the whole result

  • IPC 2021, Table 403.1, footnote a: “The fixtures shown are based on one fixture being the minimum required for the number of persons indicated or any fraction of the number of persons indicated. The number of occupants shall be determined by the International Building Code.”

  • IPC 2021, Table 403.1, footnote e: “For business and mercantile classifications with an occupant load of 15 or fewer, service sinks shall not be required.”

  • IPC 2021, Section 403.1.1: “To determine the occupant load of each sex, the total occupant load shall be divided in half.”

  • IPC 2021, Section 403.1.1: “Fractional numbers resulting from applying the fixture ratios of Table 403.1 shall be rounded up to the next whole number.”

  • IPC 2021, Section 403.1.1: “For calculations involving multiple occupancies, such fractional numbers for each occupancy shall first be summed and then rounded up to the next whole number.”

  • IPC 2021, Section 403.1.2: “The plumbing fixtures located in single-user toilet and bathing rooms, including family or assisted-use toilet and bathing rooms that are required by Section 1109.2.1 of the International Building Code, shall contribute toward the total number of required plumbing fixtures for a building or tenant space.”

  • IPC 2021, Section 403.1.1, Exception 2: “Where multiple-user facilities are designed to serve all genders, the minimum fixture count shall be calculated 100 percent, based on total occupant load.”

Uses not shown in the table, and anything these quotes do not settle: check with your local authority. This is for planning; the authority having jurisdiction decides.

Next: the accessory schedule

Open the builder with these counts filled in: water closets become toilet compartments, with the lavatories and any urinals beside them. It lists every accessory with its quantity and ADA mounting height, priced.

Build the accessory schedule for these restroomsOpens the women's room (2 compartments, 2 lavatories).

The builder takes one room at a time. The men's room is one click away: open the men's room (2 compartments, 2 lavatories).

How the calculator works

It uses the 2021 International Plumbing Code (IPC), Table 403.1, and nothing else. California has its own plumbing code with a different fixture table, and other states and cities adopt and amend codes on their own schedules, so this tool does not say which code applies to your project. The local authority having jurisdiction decides. Where the quoted text does not settle a rule, the calculator does not guess: check with your local authority.