Three layers of rules apply to a commercial baby changing station: the 2010 ADA Standards govern how a station is mounted and operated, a federal law requires them in certain federal buildings, and state and local codes decide most other projects. The ADA does not say how many stations a restroom needs.
ADA rules that reach a changing station
No ADA provision names baby changing stations. Advisory 902.1 lists baby changing tables among its examples of work surfaces, and section 226.1 requires at least 5 percent of work surfaces provided for use by other than employees to comply with 902, which sets the top at 28 to 34 in. above the finish floor (902.3). A station's release latch or handle must sit within a reach range in 308 and operate with one hand and no tight grasping (309.3 and 309.4). Section 604.3.2 keeps changing tables out of the clearance at the water closet. The full rules with verbatim quotes are on the ADA baby changing station height page.
Federal law: Public Law 114-235 (the BABIES Act)
Public Law 114-235, signed October 7, 2016, added section 3314 to Title 40 of the U.S. Code. It requires baby changing facilities in restrooms in public buildings controlled by the General Services Administration's Public Building Service, and it applies to a public building constructed, altered, or acquired by GSA on or after the date one year after enactment. The law defines a baby changing facility as a table or other device suitable for changing the diaper of a child age 3 or under, and it lists four exceptions: a restroom that is not available or accessible for public use, a restroom with clear signage pointing to a restroom with a changing table on the same floor, a building where new construction would be needed and its cost is unfeasible, and a building not subject to an alteration under section 3307 of the same title. It does not apply to private buildings. The text is on govinfo.gov.
State and local requirements
Whether a restaurant, school, hospital, or office needs a station, and in which restrooms, depends on the building code the jurisdiction has adopted and on any state or local statute. We do not summarize those here because they differ by place and change. Confirm with the authority having jurisdiction, or ask the architect who prepared the permit set.
Layouts compared
Two Koala Kare layouts cover most surface mounted projects. The figures below are the maker's, as listed on our product pages.
| Model | Layout | Size | Extends from wall when open |
|---|---|---|---|
| KB300 | Horizontal | 35-15/16 in. wide by 20-3/4 in. high | 21-3/16 in. |
| KB301 | Vertical | 20-3/4 in. wide by 35-7/8 in. high | 36-5/8 in. |
The KB310 and KB311 are the stainless steel versions of the same two layouts. Wall width and floor depth are the two limits to check on a plan: the horizontal unit takes more wall and less floor, the vertical unit the reverse.
What to confirm before ordering
- Which restrooms. Federal law and local code decide whether a station goes in the men's room, the women's room, or a family restroom. Confirm the count with the plans reviewer.
- Clearance. Along a circulation path, section 307.2 limits an object whose leading edge is more than 27 in. and not more than 80 in. above the floor to 4 in. of projection, so check the closed depth on the product page, and the open position where the station faces a path. Inside a toilet compartment, section 604.3.2 keeps the water closet clearance free of changing tables.
- Mounting. Surface mounted stations need a finished wall to mount on, and recessed stations need a wall cavity before the wall closes.
- Operation. Confirm the latch can be used with one hand, as section 309.4 requires.
Choosing a station
The stations we list from Koala Kare come in horizontal and vertical layouts, surface mounted and recessed, in polypropylene, polyethylene, and stainless steel. ASI, Bradley, and Gamco stations are listed beside them. A vertical unit needs less wall width and a horizontal one needs less floor depth in front of it. Our baby changing stations page lists every model with its open and closed dimensions, which you need to check against the 4 in. projection limit and the clear floor space in the restroom.
Send us the restroom plan with the quantity you need and we will quote the stations within one business day, or use the restroom builder to add them to a full accessory schedule.