One takeoff for a school restroom, from the compartment material down to the mop holder in the janitor closet.

A school restroom is one schedule with four buyouts inside it: compartments, washroom accessories, life safety, and the storage in the corridor outside the door. This page lists the lines a K-12 or university restroom needs, what sets each count, and where the children's dimensions in Section 604.9 change the numbers. Work down it to build a fixture and accessory schedule, or send the Division 10 spec sections and a compartment count and we will quote against them.

Written for Architects writing a Division 10 spec, GCs buying out a school restroom, and district or campus facilities staff renovating over the summer.. 14 of 28 line items can ship from the catalog today; the rest we quote.

Toilet compartments

Material first, then the accessible compartments, then hardware. The fixture count sets how many accessible compartments you owe, not the size of the room.

Line itemWhat drives itSupply
Solid plastic (HDPE) compartments, floor mounted overhead bracedThe K-12 default, because the color runs through the panel, so carving and graffiti sand out instead of forcing a panel swap.Quoted
Phenolic compartmentsSpecified where a high school or a university wants a finished face and stronger hardware mounting with the same abuse tolerance as HDPE.Quoted
Powder coated steel compartmentsThe budget line for dry staff and administrative restrooms, where touch up paint is easier than replacing a panel.Quoted
Wheelchair accessible compartment, one per toilet room minimumSection 604.8.1.1 sets it at 60 in. wide minimum, and a floor mounted water closet needs the deeper 59 in. dimension that a wall hung one does not.Quoted
Ambulatory accessible compartmentOwed once the restroom has six or more compartments, or six or more urinals and water closets combined, and it takes a side wall grab bar on both sides under Section 604.8.2.3.Quoted
Urinal screensOne screen between urinals, ordered in the compartment material and color so the room reads as one package.Quoted

Accessories at the lavatory wall

These repeat per lavatory or per room. Decide recessed or surface here, because the wall depth is a framing question, not a finish question.

Line itemWhat drives itSupply
Mirror above each lavatoryOne per lavatory, and Section 603.3 caps how high the bottom edge of the reflecting surface can sit, so the glass size decides where the top lands.Order online
Soap dispenserOne per lavatory, or a top fill multi feed system where the custodial crew wants a single fill point for a row of sinks.Order online
Recessed towel dispenser and waste receptacle unitTwo functions in one wall opening, which is what keeps used towels off a school restroom floor.Order online
High speed hand dryerTakes the towel line out of the janitorial budget, so specify a surface unit that stays inside the 4 in. projection limit or recess it.Order online
Free standing waste receptacleSized to how often custodial can empty it during the day, not to the number of lavatories.Order online
Stainless steel shelfOptional, and it is what keeps phones and books out of a wet lavatory deck.Order online

Accessories inside each compartment

Every line here multiplies by compartment, so a miscount on this section is what turns into a change order.

Line itemWhat drives itSupply
Toilet tissue dispenserOne per compartment, and a multi roll or hide a roll unit cuts the number of restock trips between passing periods.Order online
Combination tissue, seat cover, and napkin disposal unitOne recessed cabinet per compartment replaces three surface items, and a partition mounted dual access unit serves two compartments through one cutout.Order online
Sanitary napkin disposalOne per compartment in a girls' or all gender restroom, and always in the accessible compartment.Order online
Grab bars, side wall and rear wallTwo bars per accessible compartment under Section 604.5, with the top of the gripping surface 33 to 36 in. above the finish floor.Order online
Coat hookOne per compartment door, and in an accessible compartment Section 604.8.3 puts it inside the reach ranges.Order online
Napkin and tampon vendorFree vend where state law or district policy requires products at no charge, which also removes the coin mechanism from the service route.Order online

Elementary restrooms on the children's dimensions

Where the architect uses the children's exception, four lines change. Advisory 604.9 asks that one age group be applied consistently across the water closet and everything around it, so get the age group in writing before you order.

Line itemWhat drives itSupply
Grab bars at the children's heightSection 609.4 drops the top of the gripping surface to 18 to 27 in. above the finish floor at water closets for children's use.Order online
Toilet tissue dispenser at the children's heightSection 604.9.6 puts the outlet 14 to 19 in. above the floor and the dispenser 7 to 9 in. in front of the water closet, measured to its centerline.Order online
Mirror for children's useA mirror that is not over a lavatory has its own lower limit in Section 603.3, so an elementary restroom usually takes a taller glass rather than a lower frame.Order online
Wheelchair accessible compartment for children's useSection 604.8.1.1 gives it one depth, 59 in. minimum, for both wall hung and floor mounted water closets.Quoted
Paper towel dispenser within a child's reachThe age groups in Advisory 604.9 exist because children's reach ranges differ, so confirm the height with the architect instead of defaulting to the adult schedule.Order online

Life safety, egress, and the science wing

These lines sit outside the restroom and land on the same buyout, and they are the ones an inspector walks first.

Line itemWhat drives itSupply
Fire extinguishersCount is set by travel distance and hazard class under NFPA 10, not by room, and a cafeteria kitchen adds a Class K unit.Quoted
Recessed or semi recessed extinguisher cabinetsA cabinet in a school corridor has to stay inside the 4 in. projection limit in Section 307.2, which rules out most surface boxes.Quoted
Eyewash for chemistry, art, and shop roomsOSHA 1910.151(c) calls for quick drenching or flushing facilities where eyes or body may be exposed to injurious corrosive materials, and ANSI Z358.1 defines the fixture.Quoted
Drench shower where the chemical inventory warrants itSpecified alongside the eyewash where whole body flushing is needed, and the AHJ has the last word on which rooms get one.Quoted
Grade 1 door closersOne per restroom and corridor door, with delayed action where a whole class moves through the opening at once.Quoted
Panic exit devicesOn gym, cafeteria, and exterior egress doors, where the occupant load puts the opening under the panic hardware rule.Quoted

Corridor and locker room storage

Lockers are counted off the corridor elevation, door by door, and the material is decided by how wet the room gets.

Line itemWhat drives itSupply
Metal corridor lockersSingle tier where the school assigns a full locker per student, double tier where the student count outruns the wall length.Quoted
HDPE lockers for PE and poolThe answer in any room that gets mopped or splashed, because there is no coating to fail and nothing to rust.Quoted
Phenolic lockers for team roomsWhere a university wants engraved nameplates and hardware that stays tight in a sloped top bench unit.Quoted
Hook strips for the locker roomOne strip per bench run, so wet towels are not hung on locker doors and vents.Order online

Janitor closet and consumables

Division 10 puts the janitor closet on the same accessory schedule as the restrooms, and it is the section most schedules leave blank.

Line itemWhat drives itSupply
Mop and broom holder with utility shelfOne per closet, sized to the mop and broom count the head custodian actually keeps in that room.Order online
Tissue and towel stock to match the dispensersLock the paper to the dispensers you just specified, because the first mismatched reorder is what jams them.Quoted
EPA registered disinfectant and floor careSized to the nightly route and matched to the kill claims the district requires, not to the building's square footage.Quoted

What the code requires

How many accessible compartments a restroom owes

Section 213.3.1

Where toilet compartments are provided, at least one toilet compartment shall comply with 604.8.1 . In addition to the compartment required to comply with 604.8.1 , at least one compartment shall comply with 604.8.2 where six or more toilet compartments are provided, or where the combination of urinals and water closets totals six or more fixtures.
Source

Wheelchair accessible compartment size

Section 604.8.1.1

Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor mounted water closets measured perpendicular to the rear wall. Wheelchair accessible compartments for children’s use shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 59 inches (1500 mm) deep minimum for wall hung and floor mounted water closets measured perpendicular to the rear wall.
Source

Grab bar height, adult and children's use

Section 609.4

Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except that at water closets for children’s use complying with 604.9 , grab bars shall be installed in a horizontal position 18 inches (455 mm) minimum and 27 inches (685 mm) maximum above the finish floor measured to the top of the gripping surface. The height of the lower grab bar on the back wall of a bathtub shall comply with 607.4.1.1 or 607.4.2.1 .
Source

Applying one children's age group consistently (Advisory 604.9)

Section 604.9

The requirements in 604.9 are to be followed where the exception for children’s water closets in 604.1 is used. The following table provides additional guidance in applying the specifications for water closets for children according to the age group served and reflects the differences in the size, stature, and reach ranges of children ages 3 through 12. The specifications chosen should correspond to the age of the primary user group. The specifications of one age group should be applied consistently in the installation of a water closet and related elements.
Source

Children's toilet paper dispenser position

Section 604.9.6

Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor. There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow.
Source

Protrusion limit in a corridor or circulation path

Section 307.2

Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into the circulation path.
Source

School Restroom Package: common questions

Solid plastic (HDPE) for most K-12 restrooms, because the color runs through the panel, so carving and marker can be sanded and scrubbed out and the panel stays in service. Phenolic is the step up for high schools and universities that want a finished face and stronger hardware mounting. Powder coated steel is the economical choice for dry staff and administrative restrooms, where a scratch can be touched up instead of replaced.

Before you spec

Mounting heights on this job

Send the schedule, get one quote

Plans, a takeoff, or a list of part numbers. We come back in one business day with pricing and cut sheets for the whole package.