Gym and Locker Room Package: Lockers, Wet Areas, and the ADA Fixtures That Go With Them

Lockers, benches, wet area accessories, and the restroom that opens off them, in one takeoff.

An athletic or municipal locker room is bought as one room: lockers, benches, hooks, a wet area, and the restroom off it. The buyers are GCs closing out a rec center or a school gym, and facility managers replacing a room that rusted out. This page lists the package line by line, says what sets each count, and quotes the 2010 ADA Standards where a fixture has a measured requirement. Material is the first decision, because every line in the room lives in humidity.

Written for GCs, athletic directors, parks and recreation facility managers, and architects specifying an athletic or municipal locker room.. 12 of 20 line items can ship from the catalog today; the rest we quote.

Lockers, by who uses them

Humidity decides the material. Powder coated steel belongs in dry corridors, because once the finish is chipped at a hinge or a latch the steel under it rusts. The wet zone takes a material that does not corrode, and ventilation matters as much as the door material, since uniforms have to dry inside the locker.

Line itemWhat drives itSupply
Athletic lockers, single-tier, ventilated body and doorCount follows the roster, and phenolic holds hardware and engraved nameplates in a room that never fully dries.Quoted
Day-use lockers, double-tier or Z-tierDay-use openings are counted on peak occupancy rather than membership, and tiering doubles the openings in the same wall run.Quoted
Dry-side staff and corridor lockersPowder coated steel is the economical spec only where the run stays out of the shower and drying air.Quoted
Accessible lockers, one of each type at minimumSection 225.2.1 scopes 5 percent, but no fewer than one of each type, so a room with athletic, day-use, and staff lockers needs an accessible example of all three.Quoted
Locker trim: end panels, sloped tops, recess trimTrim is priced per run and per exposed end rather than per opening, and sloped tops keep tape and trash off the top of the run.Quoted
Latching: built-in combination, keypad, or padlock haspLock type is an operations decision, and Section 309.4 limits the force and the grip an accessible latch is allowed to demand.Quoted

Benches, hooks, and the dry side

Section 803.4 puts a bench complying with Section 903 inside the accessible room, and Section 903.7 requires a seat surface that is slip resistant and does not accumulate water wherever a bench sits in a wet location. That rules out the plain wood bench on most aisles between the showers and the lockers.

Line itemWhat drives itSupply
Locker room benches, pedestal or freestandingBench footage follows aisle length, and 10 51 53 keeps benches on the locker schedule instead of the furniture package.Quoted
Accessible bench, wall fixed or with back supportSection 903.3 sets the seat at 42 in. long minimum and 20 to 24 in. deep, so it is a different unit from the standard aisle bench.Quoted
Multi-hook strips and coat hooksHooks are counted per bench run and per changing cubicle, and Section 803.5 keeps the accessible ones inside the reach ranges in Section 308.Order online
Shelves above the bench runsSection 803.5 puts shelves 40 to 48 in. above the floor, which is the band to hold in the accessible changing cubicle.Order online
Full-length dressing mirrorOne per aisle is typical, and a mirror that is not over a lavatory has its own mounting limit under Section 603.3.Order online

Showers and drying areas

The shower is where an inspector takes measurements. Seat type follows the compartment type, and the grab bar layout follows the seat. Decide transfer, standard roll-in, or alternate roll-in before anything on this list is ordered, because all three change the fixture list.

Line itemWhat drives itSupply
Folding shower seats, L-shaped or rectangularOne per accessible compartment, folding in a roll-in shower under Section 610.3, with the top of the seat 17 to 19 in. above the bathroom finish floor.Order online
Shower grab barsBar count follows the compartment type, and Section 608.3.2 keeps bars off the wall above a seat and within 6 in. of adjacent walls.Order online
Curtain rods, hooks, and curtainsOne rod and curtain per shower opening, and the curtain is the item replaced most often in a public room.Order online
Recessed soap dishes and shampoo shelvesCount one per showerhead, and recessing keeps the drying lane clear of anything that catches a shoulder.Order online
Robe hooks on the drying side of the curtainOne per shower, set outside the curtain line so towels stay out of the spray.Order online

The restroom off the locker room

Hose-down cleaning and standing humidity rule out materials that would pass in an office restroom. Compartment count comes from the plumbing fixture schedule, and the accessory schedule has to match the compartment material on finish.

Line itemWhat drives itSupply
Solid plastic toilet compartmentsHDPE takes washdowns and humidity without rusting or delaminating, and the compartment count follows the fixture schedule.Quoted
Side wall and rear wall grab barsTwo per accessible compartment, with the top of the gripping surface 33 to 36 in. above the finish floor under Section 609.4.Order online
Toilet tissue dispensersOne per compartment, and jumbo roll cuts refill stops in a room that fills and empties on a bell.Order online
Soap dispensers and faucetsOne per lavatory, and a top-fill multi-feed system cuts the service points on a long gang lavatory.Order online
High speed hand dryersDryer count is set by lavatory count and queue time, and a surface unit has to sit inside the projection limit in Section 307.2 or go in an alcove.Order online
Towel dispenser and waste receptacle unitsWhere paper stays, one unit per lavatory group, recessed so the bin is out of the circulation path.Order online

Custodial and consumables

The janitor closet is on the same accessory schedule as the restroom. It is also the part of the package that gets cut at buyout and then bought twice, at retail, in the first month of operation.

Line itemWhat drives itSupply
Mop and broom holders, utility shelves, hook stripsSized to the closet wall, and the holder count follows the number of mops in service rather than the building area.Order online
Restroom paper and dispensersThe dispenser locks in the consumable for years, so settle the paper system before the dispensers ship.Quoted
Disinfectants and floor care for a wet roomA shower floor and a locker aisle are cleaned daily, so match the kill claim and the surface rather than the price per gallon.Quoted
Waste receptacles for the aisles and exitsOne at each exit and one at each towel station covers most rooms, and semi-recessed bodies stay out of the circulation path.Order online

Life safety and wall postings

Two lines that ride on the same submittal as the specialties and get inspected by different people.

Line itemWhat drives itSupply
Fire extinguisher cabinetsRecessed or semi-recessed keeps the door inside the projection limit in Section 307.2 on a corridor wall.Quoted
Fire extinguishersType, size, and spacing come from NFPA 10 and the AHJ, so the cabinet is picked after the extinguisher rather than before it.Quoted
Tackboard for hours, rules, and inspection recordsMunicipal and school rooms post at the entry, and one board on the same submittal saves a second order later.Order online

What the code requires

Shower seat height, type, and extent

Section 610.3

Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry. Where a seat is provided in an alternate roll-in type shower compartment, it shall be a folding type, shall be installed on the front wall opposite the back wall, and shall extend from the adjacent side wall to a point within 3 inches (75 mm) of the compartment entry. In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry. The top of the seat shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor. Seats shall comply with 610.3.1 or 610.3.2 .
Source

Grab bar height

Section 609.4

Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except that at water closets for children’s use complying with 604.9 , grab bars shall be installed in a horizontal position 18 inches (455 mm) minimum and 27 inches (685 mm) maximum above the finish floor measured to the top of the gripping surface. The height of the lower grab bar on the back wall of a bathtub shall comply with 607.4.1.1 or 607.4.2.1 .
Source

Grab bars in a standard roll-in shower

Section 608.3.2

Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall opposite the seat. Grab bars shall not be provided above the seat. Where a seat is not provided in standard roll-in type shower compartments, grab bars shall be provided on three walls. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls.
Source

Accessible bench size

Section 903.3

Benches shall have seats that are 42 inches (1065 mm) long minimum and 20 inches (510 mm) deep minimum and 24 inches (610 mm) deep maximum.
Source

Coat hooks and shelves in a locker room

Section 803.5

Coat hooks provided within the room shall be located within one of the reach ranges specified in 308 . Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground.
Source

How many lockers have to be accessible

Section 225.2.1

Where lockers are provided, at least 5 percent, but no fewer than one of each type, shall comply with 811 .
Source

Gym Locker Room Package: common questions

Powder coated steel is a dry corridor material. Once the finish is chipped at a hinge, a latch, or a hardware penetration, the steel under it oxidizes, and chlorine and steam speed that up. Solid plastic and phenolic do not rust at all, which is why they carry pool decks, team rooms, and PE rooms. Phenolic holds hardware and engraving better, and solid plastic is the value spec. The locker materials guide walks the comparison.

Before you spec

Mounting heights on this job